<?xml version="1.0" encoding="utf-8"?>
 | 
						|
<systemvariables version="4">
 | 
						|
  <namespace name="" comment="">
 | 
						|
    <namespace name="Device" comment="Server with ip address '192.168.1.100'">
 | 
						|
      <namespace name="Config" comment="Configuration section for this server">
 | 
						|
        <variable anlyzLocal="2" readOnly="false" valueSequence="false" unit="" name="IP" comment="The IP address of this server" bitcount="8" isSigned="true" encoding="65001" type="string" startValue="192.168.1.2" />
 | 
						|
        <variable anlyzLocal="2" readOnly="false" valueSequence="false" unit="" name="Vendor" comment="The vendor of the device" bitcount="32" isSigned="true" encoding="65001" type="int" startValue="23" minValue="2" minValuePhys="2" maxValue="23" maxValuePhys="23">
 | 
						|
          <valuetable definesMinMax="true">
 | 
						|
            <valuetableentry value="2" description="BuR" />
 | 
						|
            <valuetableentry value="23" description="Wago" />
 | 
						|
          </valuetable>
 | 
						|
        </variable>
 | 
						|
      </namespace>
 | 
						|
    </namespace>
 | 
						|
    <namespace name="Config" comment="">
 | 
						|
      <namespace name="Modbus" comment="">
 | 
						|
        <variable anlyzLocal="2" readOnly="false" valueSequence="false" unit="ms" name="RequestTimeout" comment="The maximum duration for a Modbus-UDP/-TCP request in milliseconds. After timeout a retransmission may be started (see MaxRetransmissionCount).    Use `ping` to get the maximum latency to a device, double it and add 2-3 ms for processing." bitcount="32" isSigned="true" encoding="65001" type="int" startValue="30" minValue="1" minValuePhys="1" maxValue="1000" maxValuePhys="1000" />
 | 
						|
        <variable anlyzLocal="2" readOnly="false" valueSequence="false" unit="" name="Port" comment="" bitcount="32" isSigned="true" encoding="65001" type="int" startValue="502" minValue="1" minValuePhys="1" maxValue="65535" maxValuePhys="65535" />
 | 
						|
        <variable anlyzLocal="2" readOnly="false" valueSequence="false" unit="times" name="MaxTransmissionCount" comment="How often a retransmission of a request will be sent until it gets discarded and an error is thrown." bitcount="32" isSigned="true" encoding="65001" type="int" startValue="1" minValue="1" minValuePhys="1" maxValue="10" maxValuePhys="10" />
 | 
						|
      </namespace>
 | 
						|
    </namespace>
 | 
						|
  </namespace>
 | 
						|
</systemvariables> |