TestTheStack.can

Fixed small bug
This commit is contained in:
Jonny007-MKD 2014-09-01 09:24:26 +00:00
parent 77d5eb5137
commit 4c508f7653
2 changed files with 9 additions and 17 deletions

View File

@ -1,6 +1,8 @@
/*@!Encoding:1252*/
// The state machine in this file will use all functions of the Modbus Client and check the results
// Use the SysVars to configure the test.
// The states are:
//
// 0: Get device information [ -> OnModbusReadRegistersSuccess ]
@ -130,13 +132,13 @@ void OnModbusReadBitsFailed(enum ModbusRequestError error, enum ModbusException
case 130:
writeDbg(MbError, "State %d. Reading %d output bits from 0x%04X did not work! Reason: %s", state, mbreq.Count, mbreq.Address, reason);
break;
case 200:
case 900:
if (error == FinalTimeout)
{
writeDbg(MbError, "State %d. Packet timed out! Receive window size: %d", state, s90i-1);
state = 210;
writeDbg(MbInfo, "State %d. Packet timed out! Receive window size: %d", state, s90i-1);
state = 910;
stop();
break;
return;
}
else
writeDbg(MbError, "State %d. Error while writing bit: %s", state, reason);
@ -332,7 +334,7 @@ void OnModbusReadRegistersSuccess(struct ModbusResReceiveRegisters mbres, struct
case 150:
writeDbg(MbDebug, "State %d. Successfully received three Read-Registers telegrams (as expected)", state);
if (skipOutput)
state = 900;
state = 190;
else
{
state = 160;

View File

@ -3,24 +3,14 @@
<namespace name="" comment="">
<namespace name="Device" comment="Server with ip address '192.168.1.100'">
<namespace name="Config" comment="Configuration section for this server">
<variable anlyzLocal="2" readOnly="false" valueSequence="false" unit="" name="IP" comment="The IP address of this server" bitcount="8" isSigned="true" encoding="65001" type="string" startValue="192.168.1.3" />
<variable anlyzLocal="2" readOnly="false" valueSequence="false" unit="ms" name="Interval" comment="The interval with which the device will be queried" bitcount="32" isSigned="true" encoding="65001" type="int" startValue="100" minValue="10" minValuePhys="10" maxValue="10000" maxValuePhys="10000" />
<variable anlyzLocal="2" readOnly="false" valueSequence="false" unit="" name="Vendor" comment="The vendor of the device" bitcount="32" isSigned="true" encoding="65001" type="int" startValue="2" minValue="2" minValuePhys="2" maxValue="23" maxValuePhys="23">
<variable anlyzLocal="2" readOnly="false" valueSequence="false" unit="" name="IP" comment="The IP address of this server" bitcount="8" isSigned="true" encoding="65001" type="string" startValue="192.168.1.2" />
<variable anlyzLocal="2" readOnly="false" valueSequence="false" unit="" name="Vendor" comment="The vendor of the device" bitcount="32" isSigned="true" encoding="65001" type="int" startValue="23" minValue="2" minValuePhys="2" maxValue="23" maxValuePhys="23">
<valuetable definesMinMax="true">
<valuetableentry value="2" description="BuR" />
<valuetableentry value="23" description="Wago" />
</valuetable>
</variable>
</namespace>
<namespace name="Info" comment="Some information about the device">
<variable anlyzLocal="2" readOnly="false" valueSequence="false" unit="" name="InputRegisters" comment="Number of input registers" bitcount="32" isSigned="true" encoding="65001" type="int" startValue="0" minValue="0" minValuePhys="0" maxValue="256" maxValuePhys="256" />
<variable anlyzLocal="2" readOnly="false" valueSequence="false" unit="" name="Modules" comment="The type and number of inputs of modules that are connected to the server" bitcount="8" isSigned="true" encoding="65001" type="string" startValue="DI2,DO16,DO16" />
<variable anlyzLocal="2" readOnly="false" valueSequence="false" unit="" name="SerialCode" comment="The serial code of the server" bitcount="32" isSigned="true" encoding="65001" type="int" startValue="750" minValue="1" minValuePhys="1" maxValue="10000" maxValuePhys="10000" />
<variable anlyzLocal="2" readOnly="false" valueSequence="false" unit="" name="DeviceCode" comment="The device code of the server" bitcount="32" isSigned="true" encoding="65001" type="int" startValue="881" minValue="1" minValuePhys="1" maxValue="10000" maxValuePhys="10000" />
<variable anlyzLocal="2" readOnly="false" valueSequence="false" unit="" name="InputBits" comment="Number of input bits" bitcount="32" isSigned="true" encoding="65001" type="int" startValue="2" minValue="0" minValuePhys="0" maxValue="256" maxValuePhys="256" />
<variable anlyzLocal="2" readOnly="false" valueSequence="false" unit="" name="OutputBits" comment="Number of output bits" bitcount="32" isSigned="true" encoding="65001" type="int" startValue="32" minValue="0" minValuePhys="0" maxValue="256" maxValuePhys="256" />
<variable anlyzLocal="2" readOnly="false" valueSequence="false" unit="" name="OutputRegisters" comment="Number of output registers" bitcount="32" isSigned="true" encoding="65001" type="int" startValue="0" minValue="0" minValuePhys="0" maxValue="256" maxValuePhys="256" />
</namespace>
</namespace>
<namespace name="Config" comment="">
<namespace name="Modbus" comment="">