Bachelorthesis/Modbus-CAPL/include/SysVars/testthestack.vsysvar

33 lines
No EOL
4.5 KiB
XML

<?xml version="1.0" encoding="utf-8"?>
<systemvariables version="4">
<namespace name="" comment="">
<namespace name="Device" comment="Server with ip address '192.168.1.100'">
<namespace name="Config" comment="Configuration section for this server">
<variable anlyzLocal="2" readOnly="false" valueSequence="false" unit="" name="IP" comment="The IP address of this server" bitcount="8" isSigned="true" encoding="65001" type="string" startValue="192.168.1.3" />
<variable anlyzLocal="2" readOnly="false" valueSequence="false" unit="ms" name="Interval" comment="The interval with which the device will be queried" bitcount="32" isSigned="true" encoding="65001" type="int" startValue="100" minValue="10" minValuePhys="10" maxValue="10000" maxValuePhys="10000" />
<variable anlyzLocal="2" readOnly="false" valueSequence="false" unit="" name="Vendor" comment="The vendor of the device" bitcount="32" isSigned="true" encoding="65001" type="int" startValue="2" minValue="2" minValuePhys="2" maxValue="23" maxValuePhys="23">
<valuetable definesMinMax="true">
<valuetableentry value="2" description="BuR" />
<valuetableentry value="23" description="Wago" />
</valuetable>
</variable>
</namespace>
<namespace name="Info" comment="Some information about the device">
<variable anlyzLocal="2" readOnly="false" valueSequence="false" unit="" name="InputRegisters" comment="Number of input registers" bitcount="32" isSigned="true" encoding="65001" type="int" startValue="0" minValue="0" minValuePhys="0" maxValue="256" maxValuePhys="256" />
<variable anlyzLocal="2" readOnly="false" valueSequence="false" unit="" name="Modules" comment="The type and number of inputs of modules that are connected to the server" bitcount="8" isSigned="true" encoding="65001" type="string" startValue="DI2,DO16,DO16" />
<variable anlyzLocal="2" readOnly="false" valueSequence="false" unit="" name="SerialCode" comment="The serial code of the server" bitcount="32" isSigned="true" encoding="65001" type="int" startValue="750" minValue="1" minValuePhys="1" maxValue="10000" maxValuePhys="10000" />
<variable anlyzLocal="2" readOnly="false" valueSequence="false" unit="" name="DeviceCode" comment="The device code of the server" bitcount="32" isSigned="true" encoding="65001" type="int" startValue="881" minValue="1" minValuePhys="1" maxValue="10000" maxValuePhys="10000" />
<variable anlyzLocal="2" readOnly="false" valueSequence="false" unit="" name="InputBits" comment="Number of input bits" bitcount="32" isSigned="true" encoding="65001" type="int" startValue="2" minValue="0" minValuePhys="0" maxValue="256" maxValuePhys="256" />
<variable anlyzLocal="2" readOnly="false" valueSequence="false" unit="" name="OutputBits" comment="Number of output bits" bitcount="32" isSigned="true" encoding="65001" type="int" startValue="32" minValue="0" minValuePhys="0" maxValue="256" maxValuePhys="256" />
<variable anlyzLocal="2" readOnly="false" valueSequence="false" unit="" name="OutputRegisters" comment="Number of output registers" bitcount="32" isSigned="true" encoding="65001" type="int" startValue="0" minValue="0" minValuePhys="0" maxValue="256" maxValuePhys="256" />
</namespace>
</namespace>
<namespace name="Config" comment="">
<namespace name="Modbus" comment="">
<variable anlyzLocal="2" readOnly="false" valueSequence="false" unit="ms" name="RequestTimeout" comment="The maximum duration for a Modbus-UDP/-TCP request in milliseconds. After timeout a retransmission may be started (see MaxRetransmissionCount). Use `ping` to get the maximum latency to a device, double it and add 2-3 ms for processing." bitcount="32" isSigned="true" encoding="65001" type="int" startValue="30" minValue="1" minValuePhys="1" maxValue="1000" maxValuePhys="1000" />
<variable anlyzLocal="2" readOnly="false" valueSequence="false" unit="" name="Port" comment="" bitcount="32" isSigned="true" encoding="65001" type="int" startValue="502" minValue="1" minValuePhys="1" maxValue="65535" maxValuePhys="65535" />
<variable anlyzLocal="2" readOnly="false" valueSequence="false" unit="times" name="MaxTransmissionCount" comment="How often a retransmission of a request will be sent until it gets discarded and an error is thrown." bitcount="32" isSigned="true" encoding="65001" type="int" startValue="1" minValue="1" minValuePhys="1" maxValue="10" maxValuePhys="10" />
</namespace>
</namespace>
</namespace>
</systemvariables>