<?xml version="1.0" encoding="utf-8"?>
 | 
						|
<systemvariables version="4">
 | 
						|
  <namespace name="" comment="">
 | 
						|
    <namespace name="Ethernet1" comment="Subnet: 192.168.1.">
 | 
						|
      <namespace name="Client_2" comment="Server with ip address '192.168.1.2'">
 | 
						|
        <namespace name="Config" comment="Configuration section for this server">
 | 
						|
          <variable anlyzLocal="2" readOnly="false" valueSequence="false" unit="" name="IP" comment="The IP address of this server" bitcount="8" isSigned="true" encoding="65001" type="string" startValue="192.168.1.2" />
 | 
						|
          <variable anlyzLocal="2" readOnly="false" valueSequence="false" unit="ms" name="Interval" comment="The interval with which the device will be queried" bitcount="32" isSigned="true" encoding="65001" type="int" startValue="100" minValue="10" minValuePhys="10" maxValue="10000" maxValuePhys="10000" />
 | 
						|
        </namespace>
 | 
						|
        <namespace name="Info" comment="Some information about the device">
 | 
						|
          <variable anlyzLocal="2" readOnly="false" valueSequence="false" unit="" name="Vendor" comment="The vendor of the device" bitcount="32" isSigned="true" encoding="65001" type="int" startValue="23">
 | 
						|
            <valuetable definesMinMax="true">
 | 
						|
              <valuetableentry value="2" description="BuR" />
 | 
						|
              <valuetableentry value="23" description="Wago" />
 | 
						|
            </valuetable>
 | 
						|
          </variable>
 | 
						|
          <variable anlyzLocal="2" readOnly="false" valueSequence="false" unit="" name="InputRegisters" comment="Number of input registers" bitcount="32" isSigned="true" encoding="65001" type="int" startValue="2" minValue="0" minValuePhys="0" maxValue="256" maxValuePhys="256" />
 | 
						|
          <variable anlyzLocal="2" readOnly="false" valueSequence="false" unit="" name="Modules" comment="The type and number of inputs of modules that are connected to the server" bitcount="8" isSigned="true" encoding="65001" type="string" startValue="DI2,AI2,DO16" />
 | 
						|
          <variable anlyzLocal="2" readOnly="false" valueSequence="false" unit="" name="SerialCode" comment="The serial code of the server" bitcount="32" isSigned="true" encoding="65001" type="int" startValue="750" minValue="1" minValuePhys="1" maxValue="10000" maxValuePhys="10000" />
 | 
						|
          <variable anlyzLocal="2" readOnly="false" valueSequence="false" unit="" name="DeviceCode" comment="The device code of the server" bitcount="32" isSigned="true" encoding="65001" type="int" startValue="881" minValue="1" minValuePhys="1" maxValue="10000" maxValuePhys="10000" />
 | 
						|
          <variable anlyzLocal="2" readOnly="false" valueSequence="false" unit="" name="InputBits" comment="Number of input bits" bitcount="32" isSigned="true" encoding="65001" type="int" startValue="2" minValue="0" minValuePhys="0" maxValue="512" maxValuePhys="512" />
 | 
						|
          <variable anlyzLocal="2" readOnly="false" valueSequence="false" unit="" name="OutputBits" comment="Number of output bits" bitcount="32" isSigned="true" encoding="65001" type="int" startValue="16" minValue="0" minValuePhys="0" maxValue="512" maxValuePhys="512" />
 | 
						|
          <variable anlyzLocal="2" readOnly="false" valueSequence="false" unit="" name="OutputRegisters" comment="Number of output registers" bitcount="32" isSigned="true" encoding="65001" type="int" startValue="0" minValue="0" minValuePhys="0" maxValue="256" maxValuePhys="256" />
 | 
						|
        </namespace>
 | 
						|
        <namespace name="Data" comment="The actual process image">
 | 
						|
          <variable anlyzLocal="2" readOnly="false" valueSequence="false" unit="" name="InputRegisters" comment="The values of the input registers" bitcount="32" isSigned="true" encoding="65001" type="intarray" arrayLength="2" />
 | 
						|
          <variable anlyzLocal="2" readOnly="false" valueSequence="false" unit="" name="InputBits" comment="The state of the input bits" bitcount="32" isSigned="true" encoding="65001" type="intarray" arrayLength="2" />
 | 
						|
          <variable anlyzLocal="2" readOnly="false" valueSequence="false" unit="" name="OutputBits" comment="The state of the output bits. Write here and the values will be sent to the device" bitcount="32" isSigned="true" encoding="65001" type="intarray" arrayLength="16" />
 | 
						|
          <variable anlyzLocal="2" readOnly="false" valueSequence="false" unit="" name="OutputRegisters" comment="The values of the output registers. Write here and the values will be sent to the device" bitcount="32" isSigned="true" encoding="65001" type="intarray" arrayLength="0" />
 | 
						|
        </namespace>
 | 
						|
      </namespace>
 | 
						|
      <namespace name="Client_3" comment="Server with ip address '192.168.1.3'">
 | 
						|
        <namespace name="Config" comment="Configuration section for this server">
 | 
						|
          <variable anlyzLocal="2" readOnly="false" valueSequence="false" unit="" name="IP" comment="The IP address of this server" bitcount="8" isSigned="true" encoding="65001" type="string" startValue="192.168.1.3" />
 | 
						|
          <variable anlyzLocal="2" readOnly="false" valueSequence="false" unit="ms" name="Interval" comment="The interval with which the device will be queried" bitcount="32" isSigned="true" encoding="65001" type="int" startValue="100" minValue="10" minValuePhys="10" maxValue="10000" maxValuePhys="10000" />
 | 
						|
        </namespace>
 | 
						|
        <namespace name="Info" comment="Some information about the device">
 | 
						|
          <variable anlyzLocal="2" readOnly="false" valueSequence="false" unit="" name="Vendor" comment="The vendor of the device" bitcount="32" isSigned="true" encoding="65001" type="int" startValue="2">
 | 
						|
            <valuetable definesMinMax="true">
 | 
						|
              <valuetableentry value="2" description="BuR" />
 | 
						|
              <valuetableentry value="23" description="Wago" />
 | 
						|
            </valuetable>
 | 
						|
          </variable>
 | 
						|
          <variable anlyzLocal="2" readOnly="false" valueSequence="false" unit="" name="InputRegisters" comment="Number of input registers" bitcount="32" isSigned="true" encoding="65001" type="int" startValue="7" minValue="0" minValuePhys="0" maxValue="2048" maxValuePhys="2048" />
 | 
						|
          <variable anlyzLocal="2" readOnly="false" valueSequence="false" unit="" name="Modules" comment="The type and number of inputs of modules that are connected to the server" bitcount="8" isSigned="true" encoding="65001" type="string" startValue="" />
 | 
						|
          <variable anlyzLocal="2" readOnly="false" valueSequence="false" unit="" name="SerialCode" comment="The serial code of the server" bitcount="32" isSigned="true" encoding="65001" type="int" startValue="8828" minValue="1" minValuePhys="1" maxValue="10000" maxValuePhys="10000" />
 | 
						|
          <variable anlyzLocal="2" readOnly="false" valueSequence="false" unit="" name="DeviceCode" comment="The device code of the server" bitcount="32" isSigned="true" encoding="65001" type="int" startValue="0" minValue="1" minValuePhys="1" maxValue="10000" maxValuePhys="10000" />
 | 
						|
          <variable anlyzLocal="2" readOnly="false" valueSequence="false" unit="" name="InputBits" comment="Number of input bits" bitcount="32" isSigned="true" encoding="65001" type="int" startValue="64" minValue="0" minValuePhys="0" maxValue="16384" maxValuePhys="16384" />
 | 
						|
          <variable anlyzLocal="2" readOnly="false" valueSequence="false" unit="" name="OutputBits" comment="Number of output bits" bitcount="32" isSigned="true" encoding="65001" type="int" startValue="0" minValue="0" minValuePhys="0" maxValue="16384" maxValuePhys="16384" />
 | 
						|
          <variable anlyzLocal="2" readOnly="false" valueSequence="false" unit="" name="OutputRegisters" comment="Number of output registers" bitcount="32" isSigned="true" encoding="65001" type="int" startValue="0" minValue="0" minValuePhys="0" maxValue="2048" maxValuePhys="2048" />
 | 
						|
        </namespace>
 | 
						|
        <namespace name="Data" comment="The actual process image">
 | 
						|
          <variable anlyzLocal="2" readOnly="false" valueSequence="false" unit="" name="InputRegisters" comment="The values of the input registers" bitcount="32" isSigned="true" encoding="65001" type="intarray" arrayLength="7" />
 | 
						|
          <variable anlyzLocal="2" readOnly="false" valueSequence="false" unit="" name="InputBits" comment="The state of the input bits" bitcount="32" isSigned="true" encoding="65001" type="intarray" arrayLength="64" />
 | 
						|
          <variable anlyzLocal="2" readOnly="false" valueSequence="false" unit="" name="OutputBits" comment="The state of the output bits. Write here and the values will be sent to the device" bitcount="32" isSigned="true" encoding="65001" type="intarray" arrayLength="0" />
 | 
						|
          <variable anlyzLocal="2" readOnly="false" valueSequence="false" unit="" name="OutputRegisters" comment="The values of the output registers. Write here and the values will be sent to the device" bitcount="32" isSigned="true" encoding="65001" type="intarray" arrayLength="0" />
 | 
						|
        </namespace>
 | 
						|
      </namespace>
 | 
						|
    </namespace>
 | 
						|
    <namespace name="Config" comment="">
 | 
						|
      <namespace name="Modbus" comment="">
 | 
						|
        <variable anlyzLocal="2" readOnly="false" valueSequence="false" unit="ms" name="RequestTimeout" comment="The maximum duration for a Modbus-UDP/-TCP request in milliseconds. After timeout a retransmission may be started (see MaxRetransmissionCount).    Use `ping` to get the maximum latency to a device, double it and add 2-3 ms for processing." bitcount="32" isSigned="true" encoding="65001" type="int" startValue="10" minValue="1" minValuePhys="1" maxValue="1000" maxValuePhys="1000" />
 | 
						|
        <variable anlyzLocal="2" readOnly="false" valueSequence="false" unit="" name="Port" comment="" bitcount="32" isSigned="true" encoding="65001" type="int" startValue="502" minValue="1" minValuePhys="1" maxValue="65535" maxValuePhys="65535" />
 | 
						|
        <variable anlyzLocal="2" readOnly="false" valueSequence="false" unit="times" name="MaxTransmissionCount" comment="How often a retransmission of a request will be sent until it gets discarded and an error is thrown." bitcount="32" isSigned="true" encoding="65001" type="int" startValue="2" minValue="1" minValuePhys="1" maxValue="10" maxValuePhys="10" />
 | 
						|
      </namespace>
 | 
						|
      <namespace name="TcpIp" comment="">
 | 
						|
        <variable anlyzLocal="2" readOnly="false" valueSequence="false" unit="" name="AdapterIndex" comment="Index of network interface to use" bitcount="32" isSigned="true" encoding="65001" type="int" startValue="2" minValue="1" minValuePhys="1" maxValue="20" maxValuePhys="20" />
 | 
						|
      </namespace>
 | 
						|
    </namespace>
 | 
						|
  </namespace>
 | 
						|
</systemvariables> |