<variable anlyzLocal="2" readOnly="false" valueSequence="false" unit="ms" name="Interval" comment="The interval with which the device will be queried" bitcount="32" isSigned="true" encoding="65001" type="int" startValue="1000" minValue="10" minValuePhys="10" maxValue="10000" maxValuePhys="10000" />
<variable anlyzLocal="2" readOnly="false" valueSequence="false" unit="" name="Modules" comment="The type and number of inputs of modules that are connected to the server" bitcount="8" isSigned="true" encoding="65001" type="string" startValue="DI2,DO16" />
<variable anlyzLocal="2" readOnly="false" valueSequence="false" unit="" name="SerialCode" comment="The serial code of the server" bitcount="32" isSigned="true" encoding="65001" type="int" startValue="750" minValue="1" minValuePhys="1" maxValue="10000" maxValuePhys="10000" />
<variable anlyzLocal="2" readOnly="false" valueSequence="false" unit="" name="InputRegisters" comment="The values of the input registers" bitcount="32" isSigned="true" encoding="65001" type="intarray" arrayLength="0" />
<variable anlyzLocal="2" readOnly="false" valueSequence="false" unit="" name="InputBits" comment="The state of the input bits" bitcount="32" isSigned="true" encoding="65001" type="intarray" arrayLength="2" />
<variable anlyzLocal="2" readOnly="false" valueSequence="false" unit="" name="OutputBits" comment="The state of the output bits. Write here and the values will be sent to the device" bitcount="32" isSigned="true" encoding="65001" type="intarray" arrayLength="16" />
<variable anlyzLocal="2" readOnly="false" valueSequence="false" unit="" name="OutputRegisters" comment="The values of the output registers. Write here and the values will be sent to the device" bitcount="32" isSigned="true" encoding="65001" type="intarray" arrayLength="0" />
<variable anlyzLocal="2" readOnly="false" valueSequence="false" unit="ms" name="RequestTimeout" comment="The maximum duration for a Modbus-UDP/-TCP request in milliseconds. After timeout a retransmission may be started (see MaxRetransmissionCount). Use `ping` to get the maximum latency to a device, double it and add 2-3 ms for processing." bitcount="32" isSigned="true" encoding="65001" type="int" startValue="7" minValue="1" minValuePhys="1" maxValue="1000" maxValuePhys="1000" />
<variable anlyzLocal="2" readOnly="false" valueSequence="false" unit="times" name="MaxTransmissionCount" comment="How often a retransmission of a request will be sent until it gets discarded and an error is thrown." bitcount="32" isSigned="true" encoding="65001" type="int" startValue="1" minValue="1" minValuePhys="1" maxValue="10" maxValuePhys="10" />