<variable anlyzLocal="2" readOnly="false" valueSequence="false" unit="ms" name="RequestTimeout" comment="The maximum duration for a Modbus-UDP/-TCP request in milliseconds. After timeout a retransmission may be started (see MaxRetransmissionCount). Use `ping` to get the maximum latency to a device, double it and add 2-3 ms for processing." bitcount="32" isSigned="true" encoding="65001" type="int" startValue="5" minValue="1" minValuePhys="1" maxValue="1000" maxValuePhys="1000" />
<variable anlyzLocal="2" readOnly="false" valueSequence="false" unit="times" name="MaxTransmissionCount" comment="How often a retransmission of a request will be sent until it gets discarded and an error is thrown." bitcount="32" isSigned="true" encoding="65001" type="int" startValue="3" minValue="1" minValuePhys="1" maxValue="10" maxValuePhys="10" />
<namespace name="Client_2" comment="Server with ip address '192.168.1.2'">
<namespace name="Config" comment="Configuration section for this server">
<variable anlyzLocal="2" readOnly="false" valueSequence="false" unit="" name="IP" comment="The IP address of this server" bitcount="8" isSigned="true" encoding="65001" type="string" startValue="192.168.1.2" />
<variable anlyzLocal="2" readOnly="false" valueSequence="false" unit="ms" name="Interval" comment="The interval with which the device will be queried" bitcount="32" isSigned="true" encoding="65001" type="int" startValue="100" minValue="10" minValuePhys="10" maxValue="10000" maxValuePhys="10000" />
</namespace>
<namespace name="Info" comment="Some information about the device">
<variable anlyzLocal="2" readOnly="true" valueSequence="false" unit="" name="Modules" comment="The type and number of inputs of modules that are connected to the server" bitcount="8" isSigned="true" encoding="65001" type="string" startValue="DI2," />
<variable anlyzLocal="2" readOnly="false" valueSequence="false" unit="" name="OutputRegisters" comment="The values of the output registers. Write here and the values will be sent to the device" bitcount="32" isSigned="true" encoding="65001" type="intarray" arrayLength="0" />
<variable anlyzLocal="2" readOnly="false" valueSequence="false" unit="" name="OutputBits" comment="The state of the output bits. Write here and the values will be sent to the device" bitcount="32" isSigned="true" encoding="65001" type="intarray" arrayLength="0" />